Manual of Quantitative Detection Kit (ELISA) for Human 17-Hydroxycorticosteroid (17-OHCS)

This kit can only be used for scientific research, not for medical diagnosis.

Human 17-Hydroxycorticosteroid (17-OHCS) Quantitative Detection Kit (ELISA)

user's Guide

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit kit name]

Human 17-Hydroxycorticosteroid (17-OHCS) Quantitative Detection Kit (ELISA)

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa Kit Kit Usage]

Quantitative detection of 17-hydroxycorticosteroid (17-OHCS) in human serum, plasma and related liquid samples.

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit detection principle]

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated human 17-hydroxycorticosteroid (17-OHCS) monoclonal antibody clear enzyme label coated plate. After incubation for a sufficient time, wash to remove unbound components, and then add the enzyme Standard working solution, after incubation for a sufficient time, wash to remove unbound components. Substrates A and B were added in sequence, and the substrate (TMB) was converted into a blue product catalyzed by horseradish peroxidase (HRP), which turned yellow under the action of an acid. Corticosteroid (17-OHCS) concentration was positively correlated. The OD value was measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of human 17-hydroxycorticosteroid (17-OHCS) in the sample was calculated.

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit composition]

1

Enzyme coated plate

12 holes × 8

7

Developer A liquid

6mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

6mL

3

20 times concentrated washing liquid

25mL

9

Stop solution

6mL

4

Sample diluent

6mL

10

Instructions

1 serving

5

Special diluent

6mL

11

Sealing film

2 sheets

6

Enzyme reagent

6mL

12

sealed bag

1

Remarks: The concentration of standard products (No. 1 → No. 6) is: 32, 16, 8, 4, 2, 1μg / L.

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit required and not provided reagents and equipment]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit operating steps]

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of the sample to be tested, then add 40μL of sample diluent (that is, the sample is diluted 5 times); the blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each well with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the washing plate 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Plate washing: Discard the liquid, pat dry on the absorbent paper, fill each hole with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution. Mix with a plate mixer for 30s (or shake gently by hand for 30s), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow)

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit sample requirements]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

[Precautions for Human 17-Hydroxycorticosteroid (17-OHCS) Elisa Kit]

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 1-32μg / L, beyond this range, it is calculated from the extension of the standard curve. It is not used as an accurate quantitative result. Please dilute it with a special diluent to determine the accurate result (within the range of 1-32μg / L) ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit operating procedure summary]

Prepare reagents, samples and standards

Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit detection range]

1μg / L-32μg / L

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa Kit Specifications]

96 servings / box

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa Kit Storage]

Store at 2-8 ℃, protected from light and moisture.

[Human 17-Hydroxycorticosteroid (17-OHCS) Elisa kit expiry date]

6 months

The Inport Stopper For I.V Fluid Bag is based on the polycarbonate joint formed by injection molding process, comprising of the injection‐purpose halogenated butyl rubber stopper and outer cap. Among which, the material for polycarbonate joint is the imported medical‐level polycarbonate, complying with the FDA rules; the injection‐purpose halogenated butyl rubber stopper can be chosen to use the well‐known domestic product or imported product on the request of user.

The medicine‐loading stopper is produced in the clean plant, with the partial part reaching to Class 100 under the Class 10,000 background. The main working procedures, such as the injection molding, inspection and cleaning, and assembly and etc., are designed and processed as per the cleanliness requirements at the partial level of Class 100, which passes the GMP on‐site certification and complies with the cleanliness requirements of high capacity injection medicine.

 The main production equipments, test and inspection instruments of medicine‐loading stopper have already reached to the international level and are advanced at home. Meanwhile, the full production process is conducted the strict control and management, and making product free of plasticizing agent, loading agent and lubricating agent, and free of absorption or transfer when contacting with liquid medicine, neither the pyrogen and soluble matter, thence such equipments may ensure the product quality.

The inport stopper for I.V fluid bag is mainly used for double‐hose non‐PVC soft bag.

Inport Stopper For I.V Fluid Bag

I.V Fluid Bag Inport Stopper,Infusion Bag Medical Inport Stopper,Fluid Bag Stopper

YANGZHONG HONGYUN BOTTLE CAPS MAKING FACTORY , https://www.hongyunyz.com